40
water system trouble shooting
The pump may have to be removed to gain
access to the adjusting screw. Drain the water
system before removing the pump.
To remove the pump pull the blue taps at right
angles to the pipe work and lift the pump out.
TROUBLE SHOOTING
Pump will not start, when the tap is
opened:
• Checkfuse(s).
• Checkpowersource(s),andensurethere
is sufficient voltage to run the pump.
• Ensure'pump'LEDisilluminated.
• Usingamulti-meter,ensurethereispower
at the pump. If not, refer to your dealer as
there maybe damaged cabling or a fault
with the fusebox.
• Isthepumphot?Ifso,allowtocool
before retrying.
• Hasthevehiclebeenstoredoverwinter?
wasitcorrectlywinterised?Ifno,thepump
may have frozen, causing permanent
damage.
• Thepressureswitchmayneedadjusting.
(See pressure switch paragraph in this
section for how to do this)
Pump runs, but will not pressurise system
(i.e. no or little water being discharged
from taps) - Not Pulsing:
• Ensurethatthereiswaterinthefresh
water tank.
• Checkin-linelterisfreefromdebrisand
correctly fitted.
• Ensurewatersystemhasbeenprimed
correctly, (see primming the water system
page 44), and there are no air-locks
present.
• Ensuretherearenorestrictions
in the plumbing.
• Usingamulti-meter,ensurethereispower
at the pump. If not, refer to your dealer as
there maybe damaged cabling or a fault
with the fusebox.
• Ensuretheinletsideofthepumpis
watertight and not allowing air into
the system.
• Usingamultimetercheckthatthevoltage
is between 10 and 14.5 volts. If not, refer
to your dealer.
Pump continues to run (for more than 5
seconds) after taps are closed or pump
turns on for no reason:
• Checkforleaksonthehighpressureside
of the pump.
• Ensurewatersystemhasbeenprimed
correctly, as per the handbook, and there
are no air-locks present.
• Ensurethepumpissecurelymounted.
• Ensurethepipingonthehighpressure
side of the pump is in good condition (not
blowing or deforming).
• Thepressureswitchmayneedadjusting.
(See pressure switch paragraph in this
section for how to do this)
Noisy or rough operation
• Checkforleaksonthehighpressureand
low pressure side of the pump.
• Ensurethatallpipes(especiallythose
within 150mm of the pump) are not
touching any furniture.
• Ensurethepumpissecurleymounted
Pump rapidly cycles (switches on or
off) or water pulses from taps, including
temperature pulsing:
• Checkforleaksonthehighpressureand
low pressure side of the pump.
• Ensuretherearenorestrictionsinthe
plumbing
• Thepressureswitchmayneedadjusting.
(See pressure switch paragraph in this
section for how to do this)