71
Liquid gas systems must comply with the
technical and administrative regulations of
the respective country of use (e.g. EN 1949
for vehicles in Europe).
A qualified technician must inspect/test
according to EN 1949 every two years and
a certificate issued.
The vehicle owner is always responsible for
arranging the inspection.
4. Do not operate the water heater when
refuelling the vehicle and when in the
garage.
5. During the initial operation of a brand new
appliance (or after it has not been used for
some time), a slight amount of fumes and
a certain smell may be noticed for a short
while. Remedial action is to immediately
run the heater at maximum output and to
ensure adequate room ventilation.
6. If the burner makes an unusual noise or
if the flame lifts off, it is likely that the
regulator is faulty and it is essential to have
it checked.
Technical data
Water contents: 10 Iitres
Water pressure: up to max. 2.8 bar
Type of gas: Liquid gas (propane/butane)
Operating pressure: 30 m/b
Rated thermal output: 1500 W
Gas consumption: 120 g/h
Heating time up to approx. 70ºC:
Gas operation: approx. 35 minutes
Electrical operation: approx. 70 minutes
Gas and electrical operation: approx 20 minutes.
Power consumption 12 V
Ignition: 0.17 A
Heatingup:0.08A
Standby: 0.04 A
Power consumption 230 V
Heatingup:(2A)450W
Weight (empty): Approx: 6.7 kg