73
If the appliance is not used for a prolonged
period of time, close quick-acting valve in the
gas supply line and turn off gas cylinder. Green
indicator lamp ‘Operation’ (under rotary control
knob).
When the appliance is switched on (heating
or ventilation) the green indicator lamp must
be illuminated (the fan is running). If the
indicator lamp is not illuminated, possibly
check the (main) switch. For this purpose
observe respective instructions of the vehicle
manufacturer.
During the heating operation, while the flame
is burning, the green indicator lamp lights
up with twice the intensity. This also makes
it possible to determine the instantaneous
switching point of the room temperature.
Fuses
Fig. H3
The device and control panel fuses are on the
electronic control unit on the device.
Device fuse (F1):
3.15AT–slow–(EN60127-2-3)
Control panel fuse (F3): 1.6 AT – slow –
The fine-wire fuse must only be replaced by a
fuse of the same design.
Red indicator lamp ‘Failure’
Should a failure occur, the red indicator is
illuminated permanently. Possible causes for
the failure can be e.g. no gas, insufficient
combustion air, heavily soiled rotor, defective
fuse etc. Deactivate by switching off and then
switching on again.
Opening the window switch and closing it again
is the equivalent to switching off/on at the
control panel (e.g. performing a fault reset)!
Flash operation indicates that the operating
voltage is too low or too high for the appliance
(charge battery, if necessary). In Germany, always
notify the Truma Service Centre if problems are
encountered;inothercountriestherelevant
service partners should be contacted (see Truma
Service Booklet or www.truma.com).