equipment details
76
8. Only pressure control equipment that
complieswithEN12864(invehicles)andEN
ISO 10239 (for boats) with a fixed delivery
pressure of 30 mbar must be used for the
gas system. The flow rate of the pressure
control device must correspond to at least
the maximum consumption of all devices
installed by the system manufacturer.
For vehicles we recommend the Truma
SecuMotion gas pressure regulator and the
Truma DuoComfort automatic changeover
valve for the two-cylinder system.
At temperatures of around 0°C or less the
gas pressure regulator and the changeover
valve must be operated using the EisEx
de-icing system.
Controller connecting hoses that meet national
regulations must always be used in the
respective country for which the equipment
is destined. These hoses must be checked
regularly for brittleness. Winter-proof special
hoses must always be used if the equipment is
operated during the winter.
If the pressure regulator is exposed to weather
conditions – especially on trucks – always make
sure to protect the regulator using the Truma
protective cover (standard accessory in truck
attachment kit).
Technical data
determinedinaccordancewithEN624or
Truma test conditions
Type of gas:
Liquid gas (propane/butane)
Operating pressure:
30 mbar (see data plate)
Rated thermal output
Highsetting:2400W
Low setting: 1200 W
Gas consumption
Highsetting:200g/h
Low setting: 100 g/h
Air flow rate
Highsetting:approx.78m3/h
Low setting: approx. 49 m3/h
Current input at 12 V
Highsetting:1.1A
Low setting: 0.6 A
Current input at 24 V
Highsetting:0.7A
Low setting: 0.4 A
Standby:
0.01 A
Weight:
approx. 4.7 kg
Declaration of conformity:
The Trumatic E 2400 has been tested by the
DVGW and complies with the gas equipment
directive (90/396/EEC) and the other applicable
EC directives. The following CE Product Ident.
No.isavailableforEUcountries:
CE-0085AP0008.
The heater complies with heater directive
2001/56/EC and supplements 2004/78/EC
and 2006/119/EC and bears the type approval
number: e1 00 0144.
The heater complies with vehicle engine
interference suppression directive 72/245/EEC
with supplements 2004/104/EC and 2005/83/
EC, and bears type approval number:
e1 03 2605.
The heater complies with EMC directive
89/336/EEC and low voltage directive
72/23/EEC.
trumatic lpg heater