86
3. Use rotary switch (B) to regulate
the temperature in the main
refrigerator compartment.
Note:Iftheoperatingdisplayfailstolightup(
it lights up ‘red’ at AES models ) the device is
not in operation. (See troubleshooting section).
Mains power
This option should only be selected where the
supply voltage of the connection for power
supply corresponds to the value specified on
the data plate. Any difference in values may
result in damage to the appliance.
A
C
1. Set energy selector switch (A) to 230V .
2. Operating display ‘C’, 230V lights ‘green’.
Appliance is in function.
B
3. Use rotary switch (B) to regulate
the temperature in the main
refrigerator compartment.
Note:Iftheoperatingdisplayfailstolightup(it
lights up ‘red’ at AES models) the device is not
in operation.
Gas operation
• Therefrigeratorshouldonlybeoperated
using liquid gas (propane, butane). Do not
use town gas or natural gas.
• Iftherefrigeratorisoperatedduringtravel
using gas, the precautions stipulated by
the legislation in the respective country
must be taken (in conformity with the
EuropeanstandardEN732).
• Operatingtherefrigeratorwithgasisnot
permitted during travel in France and
Australia.
• Asabasicrule,operationusinggasis
prohibited in petrol stations.
1. Open the valve of the gas cylinder
2. Open the shut-off valve to the gas supply.
A
C
3. Set energy selector switch (A) to gas
4. Setrotaryswitch(B)to‘MAX’position.
The ignition process is activated automatically,
accompanied by a ticking sound approx. 30 sec.
Upon successful ignition, the display LED (C)
‘Gas’ lights yellow. The refrigerator is in function.
Use rotary switch (B) to regulate the temperature
in the main refrigerator compartment.
Gas faults
In the event of a gas fault (e.g. gas cylinder
empty), the operating display (C) flashes yellow.
A
C
Remedies:
Set the energy selector switch (A) to
position ‘OFF’.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
refrigerators