equipment details
93
Before calling the authorised Service
Department, please check whether:
1. The instructions in the section ‘Using the
refrigerator’ have been followed.
2. The refrigerator is not tilted excessively.
3. It is possible to operate the refrigerator
with an available power source
Note:TheSevenSeriesrefrigeratorrequires
a constant 12 volt supply for the fridge to
operate on gas. Disconnecting the leisure
battery will switch off the gas operation of the
fridge.
MAINTENANCE
• Worksongascomponentsandelectrical
installation may only be carried out by
authorised personnel. We recommend to
contact your Dometic Service Centre.
• EN1949stipulatesthattheappliance´sgas
equipment and its associated fume system
must be inspected after installation and a
certificate issued.
Afterwards a qualified technician must
inspectaccordingtoEN1949everytwo
years and a certificate issued.
It is the user’s responsibility to arrange for
inspections after purchase.
• Itisrecommendedthatthegasburner
be inspected and cleaned as necessary
at least once a year. We recommend
maintenance following an extended
shutdown of the vehicle.
PRODUCT LIABILITY
ProductliabilityofDometicGmbHdoesnot
include damages which may arise from faulty
operation, improper alterations or intervention
in the equipment, adverse effects from the
environment such as changes in temperature
and air humidity, which may impact the
equipment itself or the direct vicinity of the
equipment or persons in the area.
ENVIRONMENTAL HINTS
RefrigeratorsmanufacturedbyDometicGmbH
are CFC-free.
Ammonia (a natural compound of hydrogen
and nitrogen) is used in the cooling unit
asacoolant.Thenon-ozone-hazardous
cyclopentan is used as a propellant in the
manufacture of the PU foam insulation.
DISPOSAL
In order to ensure that the recyclable
packaging materials are re-used, these should
be sent to the usual local collection system.
The appliance should be transferred to a
suitable waste disposal company that will
ensure re-use of the recyclable components
and proper disposal of the rest.
For eco-friendly draining of the coolant from all
absorber refrigeration units, a suitable disposal
plant should be used.
ENERGY SAVING TIPS
• Atanaverageambienttemperatureof
approx. 25°C, it is sufficient to operate
the refrigerator at the middle thermostat
setting (for both gas and mains voltage).
• Wherepossible,alwaysstoregoodsthat
have previously been cooled.
• Donotpositiontherefrigeratorin
direct sunlight.
• Constantcirculationofairmustbe
supplied to the refrigerator unit.
• Defrostregularly.
• Openthedooronlyforashorttimewhen
removing goods from the refrigerator.
• Runtherefrigeratorforabout12hours
before filling it.