1 Product Overview
© Copyright Reserved Autonics Co., Ltd. 11
1 Product Overview
1.1 Features
Prescale value setting range
- 6-digit model: 0.00001 to 99999.9/ 4-digit model: 0.001 to 999.9
Communication function supported (communication model): RS485 (Modbus RTU)
One-shot output time setting range: 0.01 sec to 99.99 sec by setting per 10ms
[Counter]
9 input modes/ 11 output modes
BATCH counter, Count start point (counting initial value) setting function
[Timer]
13 output modes
Various time setting range
- 6-digit model: 0.001 sec to 99999.9 hour/
4-digit model: 0.001 sec to 9999 hour
'0' time setting function
Selectable timer memory retention function for indicator model
1.2 Components and Accessories
1.2.1 Components
Make sure all of the above components are included with your product package before use.
If a component is missing or damaged, please contact Autonics or your distributor.

Table of Contents