Page - 6
Please note the following recommended water chemistry parameters are for residential pool /
spa applications only. Follow local regulatory guidelines for any commercial pool applications.
Table 1
POOL SPA
Parameter Units Min Ideal Max Min Ideal Max
Free Chlorine ppm mg/L 1.0 2.0 - 4.0 5 2.0 3.0 - 4.0 10
Combined Chlorine ppm mg/L 0.0 0.0 0.2 0.0 0.0 0.5
pH ppm mg/L 7.2 7.2 -7.8 7.8 7.2 7.2 -7.8 7.8
Total Alkalinity ppm mg/L 60 80 - 100 180 60 80 - 100 180
Calcium Hardness ppm mg/L 150 200 - 400 1000 100 150 - 250 1000
Salt ppm mg/L 2000 2500 - 4500 ** 2000 2500 - 4500 **
Cyanuric Acid (stabilizer) ppm mg/L 0 30 - 50 *** 0 30 - 50 ***
** Typically 6,000 ppm (mg/L) or less is recommended; unit can operate with levels as high as 35,000+
ppm (mg/L).
*** This is dictated by state or local codes but is typically 80 ppm (mg/L).
See "Basic Water Chemistry" and "Using the Saturation Index" sections later in this manual for further
information concerning pool / spa water chemistry maintenance requirements. Refer to the
"Troubleshooting" section for assistance with resolving low or high chlorine issues.
SECTION 4 - SPECIFICATIONS AND APPROVALS
4.1 Specifications
SPECIFICATION
75041A, 75041A-XX
(when converted to
110V-120V in the field)
75041A,
75041A-XX
75043A, 75043A-XX
(when converted to
110V-120V in the field)
75043A,
75043A-XX
Input Power: 110-120 Vac 2.0A 220-240 Vac 1.0A 110-120 Vac 2.0A 220-240 Vac 1.0A
Cell Maximum Chlorine Output:
PPC1 0.8 lb. / day (15.1 g/hr) (standard) 0.8 lb. / day (15.1 g/hr) (standard
PPC2 not applicable 1.06 lb. / day (20.0 g/hr) (standard)
Manifold Type PPM1 & PPM1M PPM2 & PPM2M
Standard Cell PPC1 PPC2
Manifold Flow rates:
PPMxx (standard) Minimum 20 gpm (76 L/min); Maximum 70 gpm (265 L/min)
CoPilot Ozone
(optional)
Minimum 25 gpm (95 L/min); Maximum 70 gpm (265 L/min)
Maximum Manifold
Pressure
75 psi (586 kPa)
Cover Switch
Compatible
Models
75041A & 75043A (Discontinued models 75040A & 75042A)