Page - 23
7.6.g Display Temperature
Choose to either show or hide the water temperature on the normal display screen.
1.
Press MENU, press △ or▽ until “Installer menu” is displayed, then press and hold SELECT
(approximately 13 seconds) until “Installer menu” is displayed again and is accessible.
2.
Press △ or▽ until “Display temp” is displayed, then press SELECT. (“Show temperature” is the
factory setting.)
3.
Press △ or▽ until “Show temperature” or “Hide temperature” is displayed. Choose desired option
and then press SELECT.
4.
Press △ or▽ until “End menu mode” is displayed, then press SELECT.
Note that even if the Display Temp feature is turned off, the temperature can be viewed in the
“Test Pool Pilot” menu for diagnostic purposes.
7.6.h Set Reverse Time
Program Cell’s self-cleaning cycle.
CAUTION - Failure to heed the following may result in equipment damage.
l Reduced polarity reversing cycle times will reduce cell life and should only be used due to uncontrollable
scale formation on the cell. Always test and adjust water balance, before attempting scale control via
shortening reverse period. See "Using the Saturation Index" on page 46.
1.
Press MENU, press △ or▽ until “Maintenance menu” is displayed, then press SELECT.
2.
Press △ or▽ until “Set reverse time” is displayed, then press SELECT (4 hours is the factory
setting).
3.
Press △ or▽ until the desired cycle time (2, 4, 8, or 16 hours) is displayed, then press SELECT.
4.
Press △ or▽ until “End menu mode” is displayed, then press SELECT.
7.6.i Force Reverse
Note: This is a diagnostic tool only, and should not be used unless a problem is suspected.
Program the cell to activate a Force Reverse cycle and verify if the system is reversing polarity
(self-cleaning). There will be a 40 second delay, after selecting “End menu mode”, before
reversing takes place.
1.
Press MENU, press △ or▽ until “Maintenance menu” is displayed, then press SELECT.
2.
Press △ or▽ until “Force reverse” is displayed, then press SELECT.
3.
“Cell reversing” will display temporarily in 40 seconds.
4.
Press △ or▽ until “End menu mode” is displayed, then press SELECT.
5.
The “.” (period) on the end of 2nd line of the display will either appear or disappear, based on its
previous state, to indicate cell power polarity has reversed.
7.6.j Enable / Disable Audio Alarm
Note: If alarm is due to low or no water flow, the Audio Alarm will automatically silence in
10 minutes. Upon restoration of flow, normal Audio Alarm operation will resume.
1.
Press MENU, press △ or▽ until “Owner options” or “Installer menu” is displayed, then press
SELECT.
2.
Press △ or▽ until “Audio alarm” is displayed, then press SELECT.
3.
Press △ or▽ until “On or Off” is displayed, then press SELECT.
4.
Press △ or▽ until “End menu mode” is displayed, then press SELECT.