11.
PARAMETER X/XY REMARK DEFAULT
P18.x
Check Weight Stability Range
0-2
0 = ±0.5d 1 = ±1d 2 = ±1.5d 3 = ±2d
4 = ±3d 5 = ±4d 6 = ±5d 7 = ±6d
8 = ±7d 9 = ±8d
1
P19.x
Overload Limit Range
0-9
0 = FS+0d 1 = FS+9d 2 = 101%FS 3 = 102%FS
4 = 103%FS 5 = 110%FS 6 = 120%FS 7 = 150%FS
8 = 200%FS 9 = No Limitation
1
P20.x
Backlight ON/OFF Mode
0-2
0 = Always OFF
1 = Always ON
2 = Auto ON/OFF
Auto OFF when scale is stable
with no key operaon for 10 seconds.
Auto ON when scale is unstable
and there is key operaon
2
P21.x
LCD Contrast Level
0-4
0 = Very Low
1 = Low
2 = Medium
3 = High
4 = Very High
3
SCALE CABLE HOST
DB9 Female DB9 Male DB9 Female DB9 Male
PIN2 TXD 2 2 PIN2 RXD
PIN3 RXD 3 3 PIN3 TXD
PIN5 GND 5 5 PIN5 GND
PIN4 DSR 4 4 PIN4 DTR
PIN6 DTR 6 6 PIN6 DSR
PIN7 CTS 7 7 PIN7 RTS
PIN8 RTS 8 8 PIN8 CTS
PIN1 NC 1 1 PIN1 NC
PIN9 NC 9 9 PIN9
RS232/USB COMMUNICATIONS
RS232 CONNECTION BETWEEN SCALE & HOST