SYSTEM SET UP
14.
That operation can be lock by password. The password is set in PC and can be changed at anytime.
Set menu items as below:
@ IP address: set IP address of label scale
 / Subnet mask: set the subnet mask of the scale
 /  Gateway: set the gateway of the scale
D Print density set: press  /  to select 0~7,from low to high, total 8 levels
V Print speed set: press  /  to select 0~7, from fast to slow, total 8 levels
S Select paper type: press  /  to select 0~1, total 2 types: 0:label,1:Receipt (small ticket)
A Paper position fine-tuning: press  /  to select -8~+8 , total 17 offset, adjust to most
suitable starting position
 Label style selection: D0 or D1 tag with / style 
T Date adjusting: set current date and time
N 
 Whether to print weight unit: select to print weight unit or not
 Whether to print price unit: select to print price unit or not
J Decimal digits in unit price: set decimal digits in unit price
 Set default barcode type: set barcode type.(0~99, the details refer to appendix two in
software user manual)
X Total price precision: set total price precision(1: N.N0, 2: N.NN, 3: N.N)
Total price carry set: set carry value.(for example round, that is 5)
W Print time: set print time or not.(time format is hour and minute)
Y 
G Use after discount price or not: set barcode to print after discount price or not
 Display items in weight field: set 0: weight, 1: quantity
Q Print delete line mark: set 0: print, 1: not
 Select barcode width: 0: wide, 1: narrow
E The supplementary of default information 1 :0 means not default information1
F The supplementary of default information 2 :0 means not default information2
Discount goods belong to special department: setting if discount goods belong to special
department or not
R IP setting on the host machine: using this scale as the host machine to set IP address, to
connect other scales
P Statistics function mode: Choosing “yes” or “not ” to open statistics function mode for sales
goods
1. Press [set] button and hold on 3s to enter system setting status.
2. Press  or or direct number key accordingly to select item.
3. Press [PRN/ENTER] button to confirm.
NOTE: In menu, 0=not, 1=yes, if others, will note.