Avantco 178APT27HC - Minimum Temperature Limit (r1); Maximum Temperature Limit (r2)

Avantco 178APT27HC
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Temperature
Controller Settings
/C1= Probe 1 differential
-50.0° to 50.0°;
Default = 0° (Fig. 4)
Use up or down arrow to change, then press
"Set" button to keep the option.
/C2 = Probe 2 differential
(Not used on Refrigerators)
(Fig. 5)
rd = Set temperature differential
0°F to 19°F is adjustment range
Default = 5°F (Fig. 6)
Use up or down arrow to change, then press
"Set" button to keep the option.
r1 = Minimum set temperature allowed
-50°F to r2
Default = 33°F (Fig. 7)
Use up or down arrow to change, then press
"Set" button to keep the option.
r2 = Maximum set temperature allowed
r1 to 200°
Default = 43° (Fig. 8)
Use up or down arrow to change, then press
"Set" button to keep the option.
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8