Controller Settings
c0 = Compressor and fan start delay
0 to 100 minutes
Default = 2 minutes (Fig. 9)
Use up or down arrow to change, then press
"Set" button to keep the option.
dl = Time between defrosts
0 to 199 hours
Default = 6 hours (Fig. 10)
Use up or down arrow to change, then press
"Set" button to keep the option.
dt = Defrost end temperature or set point
-50°F to 130°F
Not used on refrigerators (Fig. 11)
Use up or down arrow to change, then press
"Set" button to keep the option.
dP = Maximum defrost time
1 to 199 minutes
Default = 20 minutes (Fig. 12)
Use up or down arrow to change, then press
"Set" button to keep the option.