In Recovery Mode, you can
only use HD1 monitor and
Ethernet cable connected to
GLAN1. A message 'Starting
System…' appears for about
50 seconds at system
startup.
Changing camera driver mode from automatic
to manual and the reverse, or changing the
camera cascade setup requires following a
specific procedure: see below.
In I/O Connections>Cameras>General,
select Driver mode as Automatic if all the
cascaded cameras are of the same
model. Otherwise, select Manual and
select manually the proper Driver for
each camera input, in the order in which
they will be cascaded. Disable all the
intermediate inputs that will not be
cascaded.
Power off the system.
Insert the three connectors of the special
cable for the first camera to the sockets
on the back of the first camera; pay
attention to insert the 8-pin connector to
the IN RS232C socket of the main
camera.
Connect a crossed VISCA cable from the
OUT RS232C connector of the first
camera to the IN RS232C connector of
the second camera.
Repeat with additional crossed VISCA
cables if you have a third camera for
XT7000 or more cameras when using an
XT camera switch.
Connect each additional camera to its
power source and to XT HD or DVI input,
or to the proper HD slot of the XT Camera
Switch.
Power on the system.
Flex camera can be cascaded
only as last camera in the
chain.
Some older Flex camera
models do not support
cascading. Please check that
the Flex camera (Model VC-
B20DRV) serial number
(available in a label on the
bottom of the camera as
aside) is higher than
V13C04411 or is in the
format V13xxyyzzzz (without