EasyManua.ls Logo

AVE AF921 - Behaviour of the system in alarm status

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Behaviour of the system in alarm status
Disactivated System
24h tampering
In the event of control panel, detector or keypad tampering:
low-intensity acoustic signal emitted by the control panel buzzer for 3 minutes
24h technical alarm
In the event of a technical alarm:
low-intensity acoustic signal emitted by the control panel buzzer for 15
seconds
TEC output enable for 15 seconds
Panic
By enabling the panic alarm manually through the remote control or the keypad:
Acoustic signal emitted by the AF53901R outdoor sounder for 3 minutes
PAN output enable for 15 seconds
Robbery
By enabling the robbery alarm manually through the remote control or the keypad:
No acoustic signals
RAP output enable for 15 seconds
Note: this function can be used as a request for help.
Failure, Antiscanner
Supervision
In the event of an alarm:
ANOM output enable for 15 seconds
Note: each detector is self-disactivated after three alarms detected: the other detectors remain on.

Table of Contents