21
3INSTALLATION AND DEINSTALLATION
2.1 UNPACKING, ASSEMBLING AND CONNECTING THE MACHINE
ALS
20X
256
Checking the supply voltage setting
ALS 256: A power supply setting is not re-
quired.
ALS 20X: the labellers are designed for use
with a supply voltage of 230 V (AC) or
110 V (AC).
Check whether the voltage set matches your local
supply voltage.
[21] Permitted mains supply voltages for the two positions of the volt-
age selection switch.
To change the voltage setting:
Ensure that the mains power supply lead is un-
plugged.
Slide the switch [20A] into its other position.
To do this, insert a small screwdriver into the
groove
[20B] and push the red insert horizontally
until it stops in the opposite position (for case shown
in fig.
[20], to the left).
Switch position
Permitted mains supply
voltage
115 100-120 V (AC)
230 200-240 V (AC)
[19] Machine with splash guard (A).
[20] Voltage selection switch at the ALS 20X (setting shown in
picture: 230 V)
A
B
BA