3INSTALLATION AND DEINSTALLATION
2.2 CONNECTING THE SENSORS
ALS
20X
256
Connection Diagram
[39] Connection diagram alternativ label sensor. Jumper descrip-
tion see ch. 2.2.3 (p. 32)
Example: capacitive label sensor
Application: transparent Labels
Order numbers: A7775 (di-soric sensor including
mounting material and connection cable);
A101452 (sensor only)
See www.di-soric.de
Installation:
Tools:
Hexagon socket drivers 4/6 mm
Turn out screw [40C] and remove the dispensing
edge [40E].
Remove the screws from the bottom ends of the hol-
ding rods. Take off the dispensing edge
holder [40D].
Push the sensor holder [40A] onto the holding rods
and fix it with the thumb screw [40B].
Reinstall dispensing edge holder and dispensing
edge.
Connect the cable.
+24V
+24V
NPN-Configuration
NPN-Signal
PNP-Signal
PNP-Configuration
2,2k
1k
1k
1,5k
Signal
Input
GND
Jumper
(default: open)
1
4
3
2
2,2k
CPU
Sensor
connector
[40] L-shape dispensing edge with capacitive label sensor