EasyManua.ls Logo

AVL 415SE - Page 15

AVL 415SE
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
Maintenance
AVL 415SE Smoke Meter — Maintenance Guide
Clamping piece
rolls, axles
press fit bush
bearing
Required after 4-5
exchanges of the
filter paper roll,
or after 10 000
measurements,
or after 300 oper-
ating hours of the
pump.
Clean and lubricate all
points with Teflon
lubricant spray or
Teflon lubricant oil.
If necessary. Section Lubri-
cating and
Cleaning Intervals
on page 17,
section Lubrica-
tion Points on
page 19
Sampling probe,
sampling line
For Diesel engine:
minimum once a
week,
or after 300 oper-
ating hours of the
pump.
For low meas. emis-
sion:
once a week
For high HC
concentration:
everyday
For measuring
systems with acti-
vated option "Shop
Air" the cleaning
may be omitted or
can be performed
via the shop air
purging option
Check and clean with
compressed air.
1000 – 2000
operating hours.
Section Sampling
Probe and
Sampling Line on
page 23
Filter mat Every 300 oper-
ating hours of the
pump,
or after 10 000
measurements
Visual check and
clean if necessary with
compressed air.
- Section Cooling on
page 33
Check sampled
volume
Recommended:
every 300 operating
hours of the pump,
or after 10 000
measurements.
Necessary:
after 1 000 oper-
ating hours.
Check recommended
after:
Installing/reinstalling
the device on the test
bed.
When changing the
dead volume.
After cleaning the
device from the soot
contamination.
After repairing the
device.
Re-adjustment.
Replacement of
the glass caliber of
the volume tester
is necessary if it is
scratched or
contaminated with
dirt.
Section Sampling
Volume Check on
page 37
Component / Test Lifetime /
Service interval
Maintenance Replacement Procedure
Tab. 2