IMPORTANT SAFETY INSTRUCTIONS
Please read all instructions carefully before proceeding
further to prevent the risk of fire, electric shock, personal
injury or damage to the Blower Unit. This manual
provides a general insight on the installation and may
not include solutions for all possible issues that may
occur.
Important: Read and save these instructions.
Installer: Please leave these instructions with the
owner.
Owner: Please keep these instructions for future
reference.
In case of this manual destroyed or lost, please visit
https://www.awoco.com and download a digital version.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
PERSONAL INJURY, PLEASE READ THE FOLLOWING
CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,
OPERATE OR MAINTAIN THE BLOWER UNIT:
Always disconnect, lock and tag the power source
before installing or servicing the Blower Unit. Failure
to do so may result in fire, shock or serious injury.
Installation and eletrical wiring must be done
by qualified technician(s) in accordance with all
applicable codes and standards, including fire-rated
construction.
When cutting or drilling into walls or ceilings, please
be careful not to damage any eletrical wirings and
other hidden utilities.
Verify and ensure the rated voltage and frequency
of the Blower Unit is in compliance with the nearby
power source.
Always unplug the Blower Unit from the power
source before cleaning it.
Use the Blower Unit only as directed in this manual.
Do not use it to vent hazardous or explosive
materials or vapors.
Clean the Blower Unit regularly to prevent it become
blocked or clogged. Good air flow is essential for the
Blower Unit to work propoerly.
Do not install, repair or replace any parts of the
Blower Unit or Hood Unit unless you are instructed
to do so by the manufacturer.
Do not tamper with or modify the PCB.
This Blower Unit requires a duct to vent the air
outside. Do not vent the air into spaces within walls,
ceiliings, attics, crawl spaces or garages.
The recommended installation height for the Hood
Unit is 24" minimum and 30" maximum above the
cooking surface to the bottom of the Hood Unit.
Note
For SP-06 model: This model has a built-in
damper. Additional damper is
not needed.
For SP-08 model: Damper is not included in this
model. Please purchase it
should you prefer to have one.