AXISA1601NetworkDoorController
TX
5–6
Fullduplex:TX.
Digitalinput
Connecttopin
1toactivate,
orleaveoating
(unconnected)to
deactivate.
0tomax30VDC
Congurable(Inputor
Output)
7–8
Digitaloutput
Ifusedwithan
inductiveload,e.g.,
arelay,connecta
diodeinparallelwith
theload,toprotect
againstvoltage
transients.
0tomax30VDC,
opendrain,100mA
Important
Therecommendedmaximumcablelengthis100m(328ft).
ConguredforWiegand
FunctionPinNote
Specications
DCground(GND)
1
0VDC
DCoutput(+12V)
2
Suppliespowerto
reader.
12VDC,max
486mAcombined
forbothreaders
D0
3
D1
4
O
5–6
Digitaloutput,open
drain
21

Other manuals for Axis A1601

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis A1601 and is the answer not in the manual?

Axis A1601 Specifications

General IconGeneral
Operating SystemLinux
Power12-24 V DC
ProtocolsIPv4, IPv6, SNMPv1/v2c/v3, UPnP
USB PortsUSB 2.0
Serial PortsRS-485/RS-422