AXISA1601NetworkDoorController
Doorconnector
Two4-pinterminalblocksfordoormonitoringdevices(digitalinput).
Onlydoormonitorsupportssupervisionwithendoflineresistors.Iftheconnectionis
interrupted,analarmistriggered.Tousesupervisedinputs,installendoflineresistors.Usethe
connectiondiagramforsupervisedinputs.Seepage22.
FunctionPinNotes
Specications
DCground
1,3
0VDC
Input
2,4
Forcommunicatingwithdoormonitor.
DigitalinputorSupervisedinput
Connecttopin1or3respectivelyto
activate,orleaveoating(unconnected)
todeactivate.
0tomax30VDC
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
Relayconnector
Two4-pinterminalblocksforformCrelaysthatcanbeused,forexample,tocontrolalockor
aninterfacetoagate.
FunctionPinNotes
Specications
DCground
(GND)
1
0VDC
23