Troubleshooting
Troubleshooting
Resettofactorydefaultsettings
WARNING
Possiblyhazardousopticalradiationisemittedfromthisproduct.Itcanbeharmfultotheeyes.Donotstareat
theoperatinglamp.
Important
Resettofactorydefaultshouldbeusedwithcaution.Aresettofactorydefaultresetsallsettings,includingtheIPaddress,to
thefactorydefaultvalues.
Note
ForproductswithmultipleIPaddresseschannel1willhavetheaddress192.168.0.90,channel2willhavetheaddress
192.168.0.91andsoon.
Toresettheproducttothefactorydefaultsettings:
1.Disconnectpowerfromtheproduct.
2.Pressandholdthecontrolbuttonwhilereconnectingpower.SeeProductoverviewonpage60.
3.Keepthecontrolbuttonpressedfor15–30secondsuntilthestatusLEDindicatorashesamber.
4.Releasethecontrolbutton.TheprocessiscompletewhenthestatusLEDindicatorturnsgreen.Theproducthasbeenreset
tothefactorydefaultsettings.IfnoDHCPserverisavailableonthenetwork,thedefaultIPaddressis192.168.0.90.
5.UsetheinstallationandmanagementsoftwaretoolstoassignanIPaddress,setthepassword,andaccessthedevice.
Theinstallationandmanagementsoftwaretoolsareavailablefromthesupportpagesonaxis.com/support.
6.Refocustheproduct.
1.Pressandholdthecontrolbuttonandtherestartbuttonatthesametime.
2.Releasetherestartbuttonbutcontinuetoholddownthecontrolbuttonfor15–30secondsuntilthestatusLEDindicator
ashesamber.
3.Releasethecontrolbutton.TheprocessiscompletewhenthestatusLEDindicatorturnsgreen.Theproducthasbeenreset
tothefactorydefaultsettings.IfnoDHCPserverisavailableonthenetwork,thedefaultIPaddressis192.168.0.90.
4.UsetheinstallationandmanagementsoftwaretoolstoassignanIPaddress,setthepasswordandaccessthevideostream.
5.Releasetherestartbuttonandholdthecontrolbutton.
6.KeepthecontrolbuttonpresseduntilthepowerLEDindicatorturnsgreenandthe4statusLEDindicatorsturnamber
(thismaytakeupto15seconds).
7.KeepthecontrolbuttonpresseduntilthepowerLEDindicatorturnsgreenandthe6statusLEDindicatorsturnamber
(thismaytakeupto15seconds).
8.Releasethecontrolbutton.WhenthestatusLEDindicatorsdisplaygreen(whichcantakeupto1minute)theprocessis
completeandtheunithasbeenreset.
9.Theprocessisnowcomplete.Theproducthasbeenresettothefactorydefaultsettings.IfnoDHCPserverisavailableon
thenetwork,thedefaultIPaddressis192.168.0.90-93.
10.Theprocessisnowcomplete.Theproducthasbeenresettothefactorydefaultsettings.IfnoDHCPserverisavailableon
thenetwork,thedefaultIPaddressis192.168.0.90-95.