AXISQ6000-EMkIIPTZNetworkCamera
Setuprulesforevents
1.GotoSetup>AdditionalControllerConguration>SystemOptions>Ports&Devices>I/OPorts.
2.SelectOutputfromthedesiredI/OPortTypedrop-downlistandenteraName.
3.SelecttheI/Oport’sNormalstateandclickSave.
4.GotoEvents>ActionRulesandclickAdd.
5.SelectDoorfromtheTriggerdrop-downlist.
6.SelectDoorAlarmfromthedrop-downlist.
7.Selectthedesireddoorfromthedrop-downlist.
8.SelectDoorForcedOpenfromthedrop-downlist.
9.Optionally,selectaScheduleandAdditionalconditions.Seebelow.
10.UnderActions,selectOutputPortfromtheTypedrop-downlist.
11.SelectthedesiredoutputportfromthePortdrop-downlist.
12.SetstateActive.
13.SelectDurationandGotooppositestateafter.Thenenterthedesireddurationoftheaction.
14.ClickOK.
Tousemorethanonetriggerfortheactionrule,selectAdditionalconditionsandclickAddtoaddadditionaltriggers.Whenusing
additionalconditions,allconditionsmustbemettotriggertheaction.
Topreventanactionfrombeingtriggeredrepeatedly,aWaitatleasttimecanbeset.Enterthetimeinhours,minutesandseconds,
duringwhichthetriggershouldbeignoredbeforetheactionrulecanbeactivatedagain.
TherecordingDurationofsomeactionscanbesettoincludetimeimmediatelybeforeandaftertheevent.SelectPre-triggertime
and/orPost-triggertimeandenterthenumberofseconds.WhenWhiletheruleisactiveisenabledandtheactionistriggered
againduringthepost-triggertime,therecordingtimewillbeextendedwithanotherpost-triggertimeperiod.
Formoreinformation,seetheproduct’sbuilt-inhelp.
Triggers
Availableactionruletriggersandconditionsinclude:
•AccessPoint
-AccessPointEnabled–TriggersanactionrulewhenanaccesspointdevicesuchasareaderorREXdeviceis
congured,forexamplewhenthehardwarecongurationiscompletedoranidenticationtypeisadded.
•Conguration
-AccessPointChanged–Triggersanactionrulewhenthecongurationofanaccesspointdevicesuchasa
readerorREXdeviceischanged,forexamplewhenhardwareisconguredoranidenticationtypeisedited,
changingthewaysthroughwhichadoorcanbeaccessed.
-AccessPointRemoved–Triggersanactionrulewhenthehardwarecongurationofanaccesspointdevice
suchasareaderorREXdeviceisreset.
-AreaChanged–NotsupportedbythisversionofAXISEntryManager.Mustbeconguredbyaclientsuchasan
accessmanagementsystem,throughtheVAPIX®applicationprogramminginterface,thatsupportsthisfeature
andusedevicesthatcanprovidetherequiredsignals.Triggerstheactionrulewhenanaccessareaischanged.
-AreaRemoved–NotsupportedbythisversionofAXISEntryManager.Mustbeconguredbyaclientsuch
asanaccessmanagementsystem,throughtheVAPIX®applicationprogramminginterface,thatsupportsthis
43