AXIS Q6032 PTZ Dome Network Camera
Troubleshooting
The IP address has been
changed by DHCP
If the product and the client are on the same network, run AXIS IP Utility to locate the product.
Identify the product using its model or serial number.
Move the Axis product to an isolated network, or to one with no DHCP or BOOTP server. Set the IP
address again, using AXIS IP Utility or ARP/Ping (see the Installation Guide). Open the Setup pages
and disabled DHCP in the TCP/IP settings. Return the product to the main network. The product
now has a xed IP address that will not change.
Certicate error when using
IEEE 802.1X
For authentication to work properly, the date and time settings in the Axis product should be
synchronized with an NTP server. See
Date & Time, on page 41
.
The product is accessible locally but not externally
Router conguration To congure your router to allow incoming data trafc to the Axis product, enable the NA T-traversal
feature which will attempt to automatically congure the router to a llow access to the Axis
product, see
NAT traversal (port mapping) for IPv4, on page 44
. The router must support UPnP
TM
.
Firewall protection
Check the Internet rewall with your network administrator.
Default routers required
Check if you need to congure the router settings.
Problems with the H.264 format
No H.264 displayed in the
client
Check that the relevant H.264 connection methods and c orrect interface are enabled in the AMC
Control Panel (streaming tab). See
AXIS Media Control (AMC), on page 12
.
In the AMC Control Panel, select the H.264 tab a nd click Set to default H.264 decoder.
Check that RTSP is enabled under System Options > Network > TCP/IP > Advanced.
No multicast H.264
displayed in the client
Check with your network administrator that the multicast addresses used by the Axis product
arevalidforyournetwork.
Check with your network administrator to see if there is a rewall preventing viewing.
Multicast H.264 only
accessible by local clients
Check if your router supports multicasting, o r if the router set
tings between the client and the
product need to be congured. The TTL (Time To Live) value may need to be increased.
Poor rendering of H.264
images
Color depth set incorrectly on clients. Set to 16–bit or 32–bit color.
If text overlays are blurred, or if there are other rendering problems, you may need to enable
Advanced Video Rendering from
the Video tab in the AMC Control Panel.
Ensure that your graphic
s card is using the latest drive r. The latest drivers can usually be
downloaded from the manufacturer’s website.
Color satur ation is diffe re nt
in H.264 and Mo
tion JPEG
Modify the settings for your graphics adapter. Refer to the adapter’s documentation for more
information.
Lower frame rate than
expected
Reduce the number of applications running on the client computer.
Limit the number of s imultaneous viewers.
Check with the network administrator that there is e nough bandwidth available.
Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only
key frames.
Lower the image resolution.
53

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis Q6032 PTZ and is the answer not in the manual?

Axis Q6032 PTZ Specifications

General IconGeneral
Optical Zoom35x
Digital Zoom12x
Pan Range360° endless
Operating Temperature-40 °C to 50 °C (-40 °F to 122 °F)
Video CompressionH.264, MJPEG
Network ProtocolsIPv4, IPv6, HTTP, HTTPS, FTP, SMTP, Bonjour, UPnP, SNMP v1/v2c/v3 (MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS
PowerPoE+
Ingress ProtectionIP66
Day/NightYes