Status Page Errors
We were unable to obtain an IP address from your DHCP server
Possible Issue Troubleshooting Steps
Internet port you are using is not active. Attempt to use a dierent Internet port, or verify
that the current port is active.
Ethernet cable from WAN to Internet port is mal-
functioning.
Use a dierent Ethernet cable.
Agency network only accepts devices with static
IP addresses.
You must enter a static IP address, provided by
your IT department. For this, click on the net-
working tab and ll in the required elds.
We were unable to locate a DNS server
Possible Issue Troubleshooting Steps
Port 53 is blocked. Conrm that Port 53 is not being restricted by
your rewall.
DNS Server address(es) entered incorrectly – This
applies only when using Static IP conguration.
Return to the networking tab and verify that the
DNS Server address information has been en-
tered correctly.
We were unable to communicate with a network time server
Possible Issue Troubleshooting Steps
Appropriate port (80 or 443) is blocked. Conrm that Port 80 or 443 are not being re-
stricted by your rewall.
We were unable to communicate over a secure (HTTPS) channel
Possible Issue Troubleshooting Steps
Port 443 is blocked. Conrm that Port 443 is not being restricted by