Thank you for purchasing the MCW400A100.
This manual contains information for ensuring
correct use of the MCW400A100. It also provides
necessary information for installation, maintenance,
and troubleshooting.
This manual should be read by those who design
and maintain devices that use the MCW400A100.
Be sure to keep this manual nearby for handy
reference.
Please read the "Terms and Conditions" from the
following URL before ordering or use:
http://www.azbil.com/products/bi/order.html
Handling Precautions
Do not disassemble the MCW400A100. Doing
so might cause faulty operation.
Do not use
the MCW400A100
during the tran-
sitional period (0.5s) immediately after the
power has been turned ON.
The MCW400A100 is
a multi-channel display designed to
remotely display the instantaneous flow rate of up to four
MCS-series flow sensors. It also produces open collector
output for any flow that is within the specified limits.
Additionally, by means of RS-232C communications, a per-
sonal computer can be used to change settings or to view and
save flow-rate indications and outputs.
Display and console
Connector
Location
Install the MCW400A100 where:
There are no ignitable or flammable materials.
It is not exposed to direct sunlight (ultraviolet rays).
There are no salt particles or iron particles, and no
excessive dust.
Humidity is not excessive.
There are no organic solvents, phosphate ester
hydraulic fluid, sulfur dioxide, chlorine gas, and/or acids.
It is far from high voltage sources, welding machines,
and other sources of electrical noise.
CP-SP-1206E
MCW400A100
Multi-Channel Indicator
User's Manual
1
Be sure that the user receives this manual before the
product is used.
Copying or duplicating this user’s manual in part or in
whole is forbidden. The information and specifications
in this manual are subject to change without notice.
Considerable effort has been made to ensure that this
manual is free from inaccuracies and omissions. If you
should find an error or omission, please contact the
azbil Group.
In no event is Azbil Corporation liable to anyone for any
indirect, special or consequential damages as a result
of using this product.
2006-2012 Azbil Corporation All Rights Reserved.
NOTICE
Safety precautions are intended to ensure the safe
and correct use of this product, and to prevent dam-
age to property. Be sure to observe these safety
precautions, and be sure to read and understand
the contents of this user's manual.
SAFETY PRECAUTIONS
Use Azbil Corporation's SurgeNon if there is a risk of
power surge due to lightning. Failure to use ade-
quate protection might cause fire or faulty operation.
Use the MCW400A100 within the operating ranges
recommended in the specifications for power supply
and I/O voltage. Failure to do so might cause fire or
faulty operation.
When discarding the MCW400A100, dispose of it as
industrial waste, following local regulations.
CAUTION
OVERVIEW
PARTS NAMES AND FUNCTIONS
A. S. OUT
SW.OUT
ch
1
2
3
4
Down key:
Decreases the set value, etc.
Flow rate indicator:
Indicates the flow rate of
the channel shown by the
channel indicator.
Up key:
Increases the set
value, etc.
Output indicator:
Shows which channels have
output turned ON.
Channel indicator:
Indicates the channel
whose flow rate is shown.
Mode key:
Used for various settings.
I/O connector
Ch. 1
Ch. 2
Connector for the
MCS100 flow sensor
Ch. 3
Ch. 4
1
111
4
MOUNTING
Use the MCW400A100 within the operating ranges
given in the specifications for temperature, humidity,
voltage, vibration, shock, mounting direction, atmos-
phere, etc. Failure to do so might cause fire or mal-
function.
Do not allow lead clippings, chips or water to enter
the controller case. They might cause fire or faulty
operation.
CAUTION
CAUTION
Cautions are indicated when mishandling this
product might result in minor injury to the
user, or only physical damage to this product.
Question and Answer IconNeed help?

Do you have a question about the Azbil MCW400A100 and is the answer not in the manual?

Azbil MCW400A100 Specifications

General IconGeneral
BrandAzbil
ModelMCW400A100
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Precautions

Cautionary Notes

Indicates cautions for minor injury or physical damage from mishandling.

Handling Precautions

Disassembly and Transitional Use

Do not disassemble or use during the transitional period after power-on.

Overview

Parts Names and Functions

Display and Console

Details the flow rate indicator, channel indicator, output indicator, and control keys.

Connector

Identifies the connector for the MCS100 flow sensor and the I/O connector.

Mounting and Location

Mounting Cautions

Safety precautions for mounting, including environmental conditions and debris.

Installation Location

Specifies suitable installation locations, avoiding direct sunlight, dust, and electrical noise.

Panel Mounting Procedure

Wiring and Connections

Connector and Wiring Precautions

Handling precautions for connectors and cables, including grounding requirements.

Flow Sensor Connector and Wires

Details the pin assignments and wire colors for the flow sensor connector.

Connecting Flow Sensor Cable

Instructions for connecting the flow sensor cable, including connector handling.

Operation and Settings

Operating Mode

Describes unit operation upon power-on and how to change the displayed channel.

Setting Mode and Basic Settings

Explains how to enter setting mode and provides an overview of available settings.

Indication Settings

Covers auto-scanning and manual display on/off for flow rate indication.

Auto-scanning Indication

Details the steps to start and stop auto-scanning of channel indications.

Manual Flow Display On/Off

Explains how to turn the flow rate indication on and off manually.

Indication Settings (Continued)

Peak Hold and Bottom Hold

Allows display of peak or bottom flow rate and discusses hold function behavior.

Flow Rate Display Moving Average

Configures the 7-segment LED flow rate display moving average setting.

Basic Settings

Flow Sensor Selection

Enables setting the desired flow sensor for each channel.

Operation Mode Selection

Allows setting the desired operation mode for each channel.

Threshold and Hysteresis Settings

Threshold Settings (L1/L2)

Sets the desired threshold flow rates (L1 and L2) for each channel.

Hysteresis Settings

Sets the desired hysteresis width for each channel to prevent chattering.

Advanced Settings

Reference Flow Rate Reading

Describes reading reference flow rate in window comparator modes 2 or 3.

Zero Point Adjustment (Zero Reset)

Allows adjusting the zero point for each channel.

Output Mode and Response Time

Output Mode Inverting

Allows inverting the output of any channel in window comparator mode 4.

Switch Output Response Time

Sets the response time until the switch output turns on.

Operation Modes Details

Window Comparator Mode 1

Sets L1 and L2; SW output is not turned ON if flow rate is increasing.

Window Comparator Mode 2

L1 is set by AL and reference flow value; output is not turned ON if flow is increasing.

Window Comparator Mode 3

L1 is set by AL and reference flow value; SW output is ON when flow is within L1/L2.

Window Comparator Mode 4

L1 and L2 can be set to desired levels.

RS-232C Communications

Hardware and Software Requirements

Specifies PC requirements, OS, and software like HyperTerminal for communication.

Communications Parameters

Lists essential communication parameters like transmission speed and stop bits.

Communication Commands

Command List and Functions

Lists functions and their corresponding RS-232C commands.

Error Indication and Correction

Details error codes, indications, and suggested correction methods.

Command Descriptions

Flow Rate Indication Commands

Commands for reading flow rate (@A) and setting ON/OFF points (@PRE).

Hysteresis and Trigger Commands

Commands for setting hysteresis (@HYS) and trigger signals (@P).

Operation and Type Commands

Commands to set operation mode (@MODE) and flow sensor type (@TYPE).

Command Descriptions (Continued)

Display Control Commands

Commands for turning display off (@DIS) and setting auto-scanning (@AS).

Hold and Response Commands

Commands for peak/bottom hold (@PHL/@BHL) and response time (@DLY/@SD).

Flow Rate Display Commands

Commands for setting moving average (@FIL) and reading average setting (@F).

HyperTerminal Setup and Specifications

HyperTerminal Setup Guide

Step-by-step guide for configuring HyperTerminal for communication.

Device Specifications

Details specifications for flow rate display, output indication, and operating conditions.

External Dimensions and Panel Cutouts

Provides physical dimensions of the device and required panel cutout sizes.