Register output specifications & wiring Page 11/15
AC_ILR_BA_02_1805
5. Register output specifications & wiring
5.1. Pulse (model ILR 710)
Register wiring
External DC+: Yellow
External ground: Brown
Pulse output: White
DC Input: 8 to 24 VDC; 20 to 40mA
Outputs: Pulse output with internal pull-up resistor; optional open collector output
with output jumper removal; pulse output is scalable in pulses per liter or pulses per
gallon.
Figure 13: ILR 710 wiring
Yellow
White
Brown
Ground
Pulse
output
Output
jumper
8-24V DC input
ILR 710