Do you have a question about the Badger Meter E-Series G2 and is the answer not in the manual?
| Type | Electromagnetic Flow Meter |
|---|---|
| Display | LCD |
| Accuracy | ±0.5% of reading |
| Communication | Modbus |
| Battery Life | Up to 10 years |
| Process Connection | Flanged, Threaded |
| Enclosure | NEMA 4X |
| Power | Battery |
| Output | Pulse, Frequency |
| Material | Stainless Steel |
| Size | 1/2" to 12" |
| Fluid Temperature | -4 °F to 160 °F (-20 °C to 71 °C) |
Describes the E-Series Ultrasonic meter's technology, features, and compliance with standards.
Details the meter's construction, including housing, transducers, and wetted elements.
Explains how the meter operates by measuring flow velocity using ultrasonic signals.
Lists recommended ORION Cellular LTE-M endpoints and BEACON software for meter capabilities.
Steps to enable water pressure and temperature sensor reporting within the Beacon software.
Describes the meter's default storage mode and its display characteristics.
Explains the transition mode when water is first detected and before active mode.
Defines the normal operation state where the meter is actively measuring and recording.
Key factors to consider before installing the meter, including piping, valve placement, and clearances.
Recommendations for upstream/downstream clearances, valve types, and pipe configurations.
Step-by-step instructions for connecting and commissioning the meter into the pipeline.
Describes the meter's 9-digit Liquid Crystal Display (LCD) and its information content.
Explains how to activate and interact with the meter's LCD display.
Notes how to identify the direction of water flow on the meter.
Details various screens displayed by the meter, including total consumption.
Explains the rate of flow display, its update frequency, and units.
Describes the pressure screen, including pressure sensor limits and error indicators.
Details the temperature screen, showing water and ambient temperatures, and error codes.
Explains the alarm and operating mode screen, including codes and status indicators.
Displays the current firmware version of the meter.
Describes the 4-20 mA output set point screen and its relation to flow rate.
Explains the scaled pulse output set point screen and display resolution.
Details the measurement resolution for scaled and unscaled pulse outputs and analog output.
Describes the meter's ability to transmit status indicators via ASCII encoder protocol.
Details available output configurations including dual outputs, scaled, unscaled, and analog signals.
Information on connector types for AMR/AMI endpoints and field installation.
Provides wiring diagrams for various output combinations: Encoder/Encoder, Encoder/Scaled/Unscaled, Encoder/4-20mA, Scaled/Unscaled/4-20mA.
Details various alarm conditions including Temperature, Pressure, Empty Pipe, Measurement Error, Exceeding Max Flow, Reverse Flow, No Usage, Suspected Leak, End of Life, and Program Alert.
Lists and defines various alarm codes displayed by the meter.
Lists meter sizes, dimensions, and physical specifications like housing pressure.
Covers flow limits, pressure loss, operating performance, and maximum operating pressures.
Details temperature/humidity ranges, storage, and output (scaled, analog) specifications.
Describes the register type, display, and battery specifications including life.