33
33
english
x
x
Read/Write Head
BIS C-318-_ _
35
50
M12x1
ø 14.5
ø 5.3
24
42
186
Read / write axis
170
50
30
< 30
48
Clear zone in metal
Distances and
Velocities between
Read/Write Head
and matching
Data carrier
Matching Data Carrier Static Mode (V = 0) Dynamic Mode (V > 0)
Distance [mm] Offset [mm] at a distance [mm] of Read-/
Write
range
[mm]
Distance
[mm]
Vmax. [m/min]
1)
Read Write
1 5 10 20 30 35
Read Write
non-
flush
BIS C-108-_ _/L-SA2 0 to 6 0 to 6 ± 8.5 ± 5.5 100 5 120 70
BIS C-108-_ _/L 0 to 7 0 to 7 ± 9.5 ± 6.5 100 6 120 70
BIS C-117-05/L 0 to 7 0 to 7 ± 9.5 ± 8.5 100 6 120 70
BIS C-127-05/L 10 to 35 10 to 35 ± 25 ± 20 80 20 100 60
BIS C-128-_ _/L 7.5 7.5 ± 11 ± 8 100 6 120 70
BIS C-190-_ _/L 8 8 ± 11 ± 10 100 5 120 70
Dimensions
Standard:
Length _ _
05 = 5 m
10 = 10 m
1)
The indicated relative speeds assume a read or write of the first 4 bytes of the data carrier (bytes 0...3).
C3-slk_716464_E_1110.p65
34
english34
x
x
50
Read/Write Head
BIS C-351-_ _
170
145
4 x M6
≥ 100
6.5
16.5
30
120
35
15
≥ 60
Read /
write axis
80
≤ 50
Clear zone
in metal
see
BIS C-315
for con-
nector
dimensions
Distances and
Velocities between
Read/Write Head
and matching
Data carrier
Matching Data Carrier Static Mode (V = 0) Dynamic Mode (V > 0)
Distance [mm] Offset [mm] at a distance [mm] ofn Read-/
Write
range
[mm]
Distance
[mm]
Vmax. [m/min]
1)
Read Write
1 5 10 20 30 35
Read Write
non-
flush
BIS C-150-05/A 0 to 45 0 to 45 ± 15 ± 15 135 to
110
10 to 30 131 to
110
75 to 60
BIS C-150-11/A 45 45 ± 15 ± 15 135 to
110
10 to 30 131 to
110
75 to 60
BIS C-150-32/A 45 45 ± 15 ± 15 135 to
110
10 to 30 131 to
110
75 to 60
Dimensions
Standard:
Length _ _
05 = 5 m
10 = 10 m
1)
The indicated relative speeds assume a read or write of the first 4 bytes of the data carrier (bytes 0...3).