17
Initial Accuracy
The SG200 is a self learning product. It continuously monitors the battery
bank, and self adjusts over time to improve the accuracy of the two most
important parameters, State of Health (SoH) and State of Charge (SoC).
On new battery systems, both the State of Health and the State of Charge
values may be very close to accurate after the rst full charge and a
brief relaxation period. This is because the stored characteristics of each
battery chemistry is made with healthy batteries. If the batteries are older,
it will take a few cycles before these values can be relied upon, and you
may see signicant changes in these values during this time.
NOTE: The accuracy of the voltage and current measurements
are calibrated at the factory and do not change over time.
Display
The Display menu allows for the conguration of the Display’s colors,
intensity and power usage.
MENU OPTION DESCRIPTION
INTENSITY Change the brightness of the color display
THEME Change the color theme used on the display
PWR SAVE Choose four power saving combinations of
the Color Display, using timeout duration, and
whether the Display is dimmed or turned off
after timeout
TEST Run through a test of the Color Display
NOTE: Regardless of the INTENSITY or PWR SAVE options
selected, the SG200 Color Display will turn off the backlight after
12 hours of non-use to conserve power.