EasyManua.ls Logo

Balmar SG200 - Specifications

Balmar SG200
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Specications
Standard Conguration 1 Bank per SmartShunt Device
2 Start/Auxiliary Voltage Sense
Lines
(Up to 32 Devices including Dis-
plays and SmartShunts can be
added to single network.)
Supply Voltage Range 8-60V
MAX Bank Current-Monitored
Battery Size
1Ah-1310Ah
Average Supply Current Display On: 20mA @ 12V
Sleep Mode: 10mA @ 12V
SmartShunt Operating
Temperature:
-40°C - +85°C (-40°F- +185°F)
SmartShunt Max Current @
24°C (75°F)
350A Continuous
600A for 10 minutes
Display Values State of Charge (SoC%)
State of Health (SoH%)
Voltage (V)
Charge/Discharge Current (A)
Time Remaining (Hrs, Minutes)
History, Faults and Alerts
Communications Cable 4-wire, 22AWG, Shielded
4-pin Deutsch DT Style
Grounding Negative Battery Connection
Standards Compliance CE EMC Directive 2014/30/EU
RoHS 2 Directive 2011/65/EU
SmartShunt Dimensions Length: 4.86” (123.7mm)
Width: 3.34” (84.8mm)
Height 2.01” (50.9mm)
Gauge Minimum Depth
(with connector)
2.75 inches, 70mm
Weight SmartShunt: 0.62 lbs
Color Display: 0.16 lbs
Maximum Panel Depth for
Gauge Installation
1/2 inch (12.7mm)
Protection Rating IP65 (Display from Front)
IP67 (SmartShunt)