TECHNICAL SPECIFICATIONS
MODEL BPM 10 BPM 40 BPM 90 BPM 140
Maximum natural gas heat power
kW
10 42.5 100 142
Minimum natural gas heat power
kW
2 8.5 20 30
¹) natural gas emissions
mg/kWh
Class 3 Class 3 Class 3 Class 3
Operation
Modulating Modulating Modulating Modulating
50 Hz natural gas transformer
15kv - 25mA 15kv - 25mA 15kv - 25mA 15kv - 25mA
Maximum natural gas heat rate
Stm³/h
1.06 4.5 10.58 15.02
Minimum natural gas heat rate
Stm³/h
0.21 0.9 2.09 3.17
Maximum natural gas pressure
hPa
(mbar)
60 60 60 60
Minimum natural gas pressure
hPa
(mbar)
17 17 17 17
Maximum propane pressure
hPa
(mbar)
60 60 60 60
Minimum propane pressure
hPa
(mbar)
20 20 20 20
Absorbed electrical power* 50hz
kW
0.255 0.255 0.255 0.255
50 Hz power supply voltage
1N-230V 1N-230V 1N-230V 1N-230V
Protection rating
IP 20 IP 20 IP 20 IP 20
Control box
LME 71 LME 71 LME 71 LME 71
Operating ambient air temperature
°C
-15 ÷ +40 -15 ÷ +40 -15 ÷ +40 -15 ÷ +40
Weight with packaging
kg
8 9 13 15
Weight without packaging
kg
7 8 10 14
• Unavailable
Caloric power below reference conditions 15° C, 1013 hPa (mbar):
Natural gas: Hi = 9,45 kWh/Stm³ = 34,02 MJ/Stm³
For different types of gases and pressure values, contact our sales departments.
Minimum gas pressure, depending on the type of gas train used for obtaining max. ow rate with null pressure in the combustion chamber.
The measurements have been carried out in accordance with EN 15036 - 1 standard.
¹) NATURAL GAS EMISSIONS
Classes dened according to EN 676 standards.
Class NOx emissions in mg/kWh natural gas
1 ≤ 170
2 ≤ 120
3 ≤ 80
²) PROPANE GAS EMISSIONS
Classes dened according to EN 676 standards.
Class NOx emissions in mg/kWh propane gas
1 ≤ 230
2 ≤ 180
3 ≤ 140
ENGLISH
5 / 40
0006160310_202001