3 Installation Instructions
3.1 Handling
Proper handling ensures that the ABR will function correctly.
The ABR is designed for use in an industrial environment. It is built to withstand vibration and shock when correctly
installed. However, it is also a precision product and before and during installation it must be handled properly to avoid
damage.
Do not drop the device (exceeding shock limits)
Do not fine tune the positioning by striking the device or the bracket
Do not weld the device into position; this can cause electrostatic, heat, or reading window damage
Do not spray paint near the reader; this can cause reading window damage
3.2 Mount the Reader
Note: Mount the device at a 10° to 15° angle from the target to avoid direct reflections.
1. Rotate the connector block to the desired angle.
Connector block
rotates to 90˚ position
Figure 7. Connector Block
2. If a bracket is needed, mount the device onto the bracket.
3. Select a reading distance.
The ABR 7000 manual adjustable focus models and Liquid Lens Autofocus models are both factory focused to a
precise reading distance.
If this distance is compatible with your application, or if you have a Liquid Lens Autofocus model, you can
use the Smart Teach Interface to install the reader.
If this distance is not compatible with your application and you have a manual focus model, use the software
setup procedure described in the Instruction Manual. See
Advanced Setup for Manual Adjustable Focus
Models
on page 46.
The following table shows the Horizontal Field of View size for these factory focused reading distances:
Lens Factory Focused Reading Distance Horizontal Field of View
6 mm 85 mm (3.3 in) 121 mm (4.8 in)
9 mm 180 mm (7.1 in) 145 mm (5.7 in)
9 mm Liquid Lens Autofocus 135 mm (5.3 in)
7
109 mm (4.3 in)
12 mm 250 mm (9.8 in) 145 mm (5.7 in)
16 mm 320 mm (12.6 in) 132 mm (5.2 in)
4. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten
the mounting screws at this time.
5.
Check the device alignment.
6. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.
7
See
Aim and Autofocus the Reader—Liquid Lens Autofocus Models
on page 37to perform the autofocus to optimize the reader for other
distances.
ABR 7000 Series Barcode Reader
10 www.bannerengineering.com - Tel: + 1 888 373 6767