3.6.4 Wiring
1
+
Output 1 *
Output 2 *
Output 3 *
Trigger A (polarity insensitive)
Trigger B (polarity insensitive)
Input 2 A (polarity insensitive)
Input 2 B (polarity insensitive)
AUX RS-232 RX
AUX RS-232 TX
MAIN RS-232 TX (RS-422 TX+)
MAIN RS-232 RX (RS-422 RX+)**
MAIN RS-422 TX –
MAIN RS-422 RX – **
ID-NET network +
ID-NET network –
+
2
1
2
9
8
16
6
5
13
3
14
4
7
15
17
11
12
10
1 BN
2
BU
3 WH
4 GN
5 PK
6 YE
7 BK
8 GY
9 RD
10 VT
11 GY/PK
12 RD/BU
13 WH/GN
14 BN/GN
15 WH/YE
16 YE/BN
17 WH/GY
ABR7000
Input Power Supply
This is a typical example. Applications may vary.
Output Line Type set to PNP in Barcode Manager
If using RS-422, but not using RX+ and RX–, connect these two to –V dc or Ground
Load
Load
Load
10-30V dc
4.5-30V dc
*
**
Figure 19. PNP Inputs and Outputs