EasyManua.ls Logo

Banner ABR 7000 Series - Ethernet Connector

Banner ABR 7000 Series
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
+
Output 1 *
Output 2 *
Output 3 *
Trigger A (polarity insensitive)
Trigger B (polarity insensitive)
Input 2 A (polarity insensitive)
Input 2 B (polarity insensitive)
AUX RS-232 RX
AUX RS-232 TX
MAIN RS-232 TX (RS-422 TX+)
MAIN RS-232 RX (RS-422 RX+)**
MAIN RS-422 TX –
MAIN RS-422 RX – **
ID-NET network +
ID-NET network –
+
2
9
8
16
6
5
13
3
14
4
7
15
17
11
12
10
1 BN
2
BU
3 WH
4 GN
5 PK
6 YE
7 BK
8 GY
9 RD
10 VT
11 GY/PK
12 RD/BU
13 WH/GN
14 BN/GN
15 WH/YE
16 YE/BN
17 WH/GY
ABR7000
Input Power Supply
This is a typical example. Applications may vary.
Output Line Type set to NPN in Barcode Manager
If using RS-422, but not using RX+ and RX–, connect these two to –V dc or Ground
Load
Load
Load
10-30V dc
4.5-30V dc
*
**
Figure 20. NPN Inputs and Outputs
3.6.5 Ethernet Connector
A Standard M12 D-Coded female connector is provided for the Ethernet connection. This interface is IEEE 802.3 10 BaseT
and IEEE 802.3u 100 BaseTx compliant.
3
4
1
2
Figure 21. M12 D-Coded Female Ethernet Network Connector
ABR 7000 Series Barcode Reader
20 www.bannerengineering.com - Tel: + 1 888 373 6767

Table of Contents