2. Select your
application-specific Operating Mode from the icons over the Configuration Parameters tree area:
•
Continuous
•
One Shot
•
Phase Mode
Continuous Mode and Acquisition Trigger are shown by default.
3. Configure
the relative Operating Mode parameters from the Reading Phase parameters panel.
Different groups appear in the panel depending on the selected icons over the Configuration Parameters tree area.
6.5 Good Read Setup
1.
Click Good Read Setup.
2. Select your
specific data collection type from the icons over the Configuration Parameters tree area:
•
Code Collection
•
Code Combination
•
Code Presentation
•
Match Code
Not all data collection types are available for all Operating Modes. Incompatible data collection types are shown in
gray and cannot be selected.
The following example shows Code Combination. By default, the Expected Codes (when more than one code type
is selected), are in logical AND, which means that all codes are required to be decoded to produce a Good Read
condition.
Figure 63. Good Read Setup: Code Combination
ABR 7000 Series Barcode Reader
www.bannerengineering.com - Tel: + 1 888 373 6767 51