EasyManua.ls Logo

Banner ABR 7000 Series - ID-NET Synchronized Network

Banner ABR 7000 Series
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alone
ID-NET
Master
STP-M12D-4xx
MQDEC-1703SS-DB25
AloneAlone
Host
Switch
ID-NET
Slave #2
ID-NET
Slave #1
Phase
Mode
External
T
rigger
Continuous
Mode
1. Ethernet TCP/IP Server 1
2.
ID-NET (up to 32 devices, max network extension of 1000 m)
3. Main Serial Interface (RS232 or RS422 Full-Duplex)
4. Aux Serial Interface (RS232)
= Pass-Through Input channel
= Output channel
TCNM-ACBB1
Figure 15. ID-NET Multidata Layout (Pass-Through)
In a Pass-through layout each device supports multiple pass-through configurations to accept input from different devices
on different channels (Master reader, above). However, ID-NET Slave readers are not required to have a pass-through
configuration if they do not need to receive data from an input channel (right reader, above). The ID-NET Master always has
at least one pass-through
configuration to collect the ID-NET Slaves data and send it to the Host.
Note: Slave devices cannot receive data from a pass-through ID-NET input channel and Master devices
cannot send data on an ID-NET output channel.
All devices always support multiple output channels (that is, for data monitoring).
In a Pass-through layout each device can have a different operating mode: Continuous, One Shot, Phase Mode, etc.
3.5.5 ID-NET Synchronized Network
When the device is working Synchronized, the ID-NET connection is used to collect data from several readers to build a
multi-point or a multi-sided reading system; there can be one Master and up to 31 Slaves connected together.
The Slave readers are connected together using the ID-NET interface. Every slave reader must have an ID-NET address in
the range 1-31.
The Master reader is also connected to the Host on one of its communication channels. In the following examples the
RS232/RS422 main serial interface is used.
For a Master/Slave Synchronized layout the External Trigger signal is unique to the system; there is a single reading phase
and a single message from the Master reader to the Host computer. It is not necessary to bring the External Trigger signal
to all the readers.
In the Master/Slave Synchronized layout the Master operating mode can only be set to Phase Mode.
The Main and ID-NET interfaces are connected as shown in the following figures.