1.3.1 Indicators
3
4
5
6
7
1
2
Figure 3. Indicators—Back and Top of
Device
Indicator Color Description
1 Power Blue Indicates that the reader is connected to the power
supply
2 Ethernet
Connection
Amber Indicates connection to the Ethernet network
3 STATUS Red No read result
4 COM/Test Amber Active result output transmission on the Main serial
port
5 TRIGGER/Aim Amber Reading in progress. Do not trigger a new reading
attempt until the current attempt finishes
6 GOOD/Setup Green Reading successful
7 READY/Learn Green Ready
During the reader startup, all of the LEDs turn on for one second.
See
Smart Teach Interface
on page 36 for the colors and meanings of the five LEDs when the reader is in Smart Teach mode.
1.3.2 Diagnostic Indication
Figure 4. Diagnostic Indicators
The Status and Ready LEDs blink simultaneously to signal the presence of an error.
Diagnostic message transmission on interfaces can be enabled to provide details
about specific error conditions. See the Diagnostic Error Conditions chart in the
Diagnostic page of Barcode Manager.
1.3.3 Button
Use the button for the Smart Teach interface for quick installation without using a PC. The button can be disabled or re-
configured to perform additional functions from Barcode Manager.
See
Smart Teach Interface
on page 36.