EasyManua.ls Logo

Banner ABR 7000 Series - Page 119

Banner ABR 7000 Series
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disabled: The built-in LED array is turned off all the time. This option can be useful if using an external lighting
system.
Always ON: The built-in LED array is turned on all the time at the lowest power level. This option is useful if the LED-
array blinking disturbs the operator (Strobed operating mode).
Power Strobed: The built-in LED array is on only during the image exposure time. Different Power Strobed lighting
levels can be set.
Note: To avoid the LED array overheating, for Power Strobed settings, the program automatically limits the
range of allowed values for the Exposure Time parameter. Therefore, after changes to Internal Lighting,
recheck Exposure Time.
ABR 7000 Series Barcode Reader
www.bannerengineering.com - Tel: + 1 888 373 6767 119

Table of Contents