17
11
1
10
16
9
8
15
7
6
14
5
4
13
3
12
2
Figure 18. M12/Euro-style 17-pin male Communications, I/O, and Power Connector
Table 2: Power and I/O Pinouts for MQDC2S-17xx
Pin Wire Color Description
1 Brown Power Supply Input Voltage +
2 Blue Power Supply Input Voltage -
3 White Input Signal 2 B (polarity insensitive)
4
8
Green Transmit Data of Auxiliary RS232
5 Pink External Trigger/Input 1 B (polarity insensitive)
6 Yellow External Trigger/Input 1 A (polarity insensitive)
7 Black ID-NET network +
9
8
8
Gray Configurable
Digital Output 2 - positive pin
NPN or PNP short circuit protected and software programmable
9
8
Red Configurable
Digital Output 1 - positive pin
NPN or PNP short circuit protected and software programmable
13 White/Green Input Signal 2 A (polarity insensitive)
14
8
Brown/Green Receive Data of Auxiliary RS232
15 White/Yellow ID-NET network -
9
16 Yellow/Brown Output 3
NPN or PNP short circuit protected and software programmable
Connector
Case
n/a Cable shield connected to chassis and 17-pin connector shell
RS232 Main Serial
Interface
RS422 FD Main Serial Interface
10 Violet - RX-
10
11 Gray/Pink RX RX+
10
12 Red/Blue - TX-
17 White/Gray TX TX+
If using a TCNM-ACBB1 connection box, connect the reader using cable MQDEC-1703SS-DB25 and refer to for writing
details.
Use Cat 5e or superior M12 D-code cables, such as STP-M12D-4xx.
To meet EMC requirements:
•
Connect the reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm
8
Referenced to GND; Outputs become opto-isolated and polarity sensitive when connected through the TCNM-ACBB1 connection box. See
TCNM-ACBB1 Electrical Connections
on page 21 for connection details.
9
See
ID-NET Network Termination
on page 25 for information on resister termination.
10
If using RS422, do not leave floating. See
RS422 Full-Duplex Interface
on page 23 for connection details.
ABR 7000 Series Barcode Reader
www.bannerengineering.com - Tel: + 1 888 373 6767 17