EasyManua.ls Logo

Banner ABR 7000 Series - Page 17

Banner ABR 7000 Series
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
11
1
10
16
9
8
15
7
6
14
5
4
13
3
12
2
Figure 18. M12/Euro-style 17-pin male Communications, I/O, and Power Connector
Table 2: Power and I/O Pinouts for MQDC2S-17xx
Pin Wire Color Description
1 Brown Power Supply Input Voltage +
2 Blue Power Supply Input Voltage -
3 White Input Signal 2 B (polarity insensitive)
4
8
Green Transmit Data of Auxiliary RS232
5 Pink External Trigger/Input 1 B (polarity insensitive)
6 Yellow External Trigger/Input 1 A (polarity insensitive)
7 Black ID-NET network +
9
8
8
Gray Configurable
Digital Output 2 - positive pin
NPN or PNP short circuit protected and software programmable
9
8
Red Configurable
Digital Output 1 - positive pin
NPN or PNP short circuit protected and software programmable
13 White/Green Input Signal 2 A (polarity insensitive)
14
8
Brown/Green Receive Data of Auxiliary RS232
15 White/Yellow ID-NET network -
9
16 Yellow/Brown Output 3
NPN or PNP short circuit protected and software programmable
Connector
Case
n/a Cable shield connected to chassis and 17-pin connector shell
RS232 Main Serial
Interface
RS422 FD Main Serial Interface
10 Violet - RX-
10
11 Gray/Pink RX RX+
10
12 Red/Blue - TX-
17 White/Gray TX TX+
If using a TCNM-ACBB1 connection box, connect the reader using cable MQDEC-1703SS-DB25 and refer to for writing
details.
Use Cat 5e or superior M12 D-code cables, such as STP-M12D-4xx.
To meet EMC requirements:
Connect the reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm
8
Referenced to GND; Outputs become opto-isolated and polarity sensitive when connected through the TCNM-ACBB1 connection box. See
TCNM-ACBB1 Electrical Connections
on page 21 for connection details.
9
See
ID-NET Network Termination
on page 25 for information on resister termination.
10
If using RS422, do not leave floating. See
RS422 Full-Duplex Interface
on page 23 for connection details.
ABR 7000 Series Barcode Reader
www.bannerengineering.com - Tel: + 1 888 373 6767 17

Table of Contents