Service Mode
9-6 5976135 BARCOREALITY SIM6 21032000
Select with é or ê
then <ENTER>
<EXIT> to return.
Change Baudrate PC
Start Up
1 Push the cursor key é or ê to highlight 'Change Baudrate PC'' (menu 1).
2 Press ENTER to display the
Change Baudrate PC
menu. The actual baudrate will be highlighed.
The following baud rates are available :
230400/115200/57600/38400/19200/9600/4800/1200
3 Push the cursor key é or ê to highlight the desired baudrate.
4 Press ENTER to select.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTIME HISTORY
DIMMING
MORE...
Select with é or ê
then <ENTER>
<EXIT> to return.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTIME HISTORY
DIMMING
MORE...
WARNING
-----------------------------------------------------
RISK OF
ELECTRICAL SHOCK
______________________________________________________________
RESET LAMP RUN TIME
is reserved to
qualified
service personnel
<ENTER> to accept
<EXIT> to return.
Lamp Run Time History
What can be done ?
Getting an overview of the different lamp run times
menu 1
CHANGE BAUDRATE PC
230400
115200
57600
38400
19200
9600
4800
1200
Select with é or ê
then <ENTER>
<EXIT> to return.
menu 1
Reset Lamp Runtime
When is it allowed ?
Reset lamp run time is only allowed when a new lamp is installed.
Start Up
1 Push the cursor key é or ê to highlight 'Reset Lamp Run Time'' (menu 1).
2 Press ENTER.
The following warning will be displayed (menu 2):
Risk of electrical shock. Reset lamp run time is reserved to qualified service personnel.
If you are not qualified, press EXIT to cancel the reset operation.
menu 1
menu 2

Table of Contents