61-101-00802.EF2 (REV. G) CH. 2
January 7, 2015 Page 28 of 44
E. Disconnecting or reconfiguring
(1) Open the circuit breakers.
(2) Disconnect the test set ACFT connector from aircraft wiring plug or
the adapter cable.
(3) Disconnect the test set IND connector from the indicator or adapter
cable.
(4) Disconnect the adapter cable from the aircraft wiring and indicator.
(5) Connect the aircraft plug to indicator.
(6) Return the aircraft to original configuration.