EasyManua.ls Logo

Baumuller b maxx BM4400 - following_error_time_out Conversion

Baumuller b maxx BM4400
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection diagrams
Instruction Handbook b maXX (BM4-F-)ENC-XX (Encoder module)
Document No.: 5.01042.12 Baumüller Nürnberg GmbH
62
of 102
7.3
Construction guidance connection cable for (BM4-F-)ENC-17
m Sine cosine encoder with SSI interface and 5V encoder supply
Construction guidance:
1 Use the following materials:
m Cable: LiYCY 5 x (2 x 0.14) + 2 x 0.5 mm², Cu braiding with at least 85 % opt. overlap
m Sub-D connector. 15-pin, male
m Suitable encoder plug
2 Connect the cable shield with the cabinet of the circular connector and with the shield
of the Sub-D connector
Figure 12: Connection cable (BM4-F-)ENC-17
NOTE
The connection cable is not offered by Baumüller Nürnberg GmbH and must be made
by the user.

Table of Contents

Other manuals for Baumuller b maxx BM4400

Related product manuals