Connection guidance connection cable for BM4-F-ENC-08
m Sine cosine encoder with commutation
Construction guidance:
1 Use the following materials:
m Cable: 6 x (2 x 0.14) + 2 x 0.5 mm, Cu braiding with at least 85% opt. overlap
m Sub-D connector. 15-pin, male
m Suitable encoder plug
2 Connect the cable shield with the cabinet of the circular connector and with the shield
of the Sub-D connector
Figure 14: Connection cable (BM4-F-)ENC-08
NOTE
A broken wire of the reference signal cable [R+], [R-] or commutation signal cable
[C+], [C-], [D+], [D-] is not detected by the controller.
NOTE
The connection cable is not offered by Baumüller Nürnberg GmbH and must be made