5.6 Connecting diagrams
5.6.1 Filling information
The Baxi 600 Combi is supplied with an "Easy-Fill" permanent filling link.
The permanent filling link is a device to allow filling and repressurising of
the heating system. The link has been tested and approved to be left con
nected after use. It is not necessary to remove any temporary loop or oth
er part of the device after filling and repressurising.
Filling & repressurising is achieved by the operation of a spring loaded
green lever incorporated in the cold mains inlet part of the link. Full fitting
and operating instructions are included with the permanent filling link.
If not using the "Easy-Fill" permanent filling link normal regulations apply.
A
Domestic hot water mains inlet
B
Central heating return
C
Stop valve
D
Double check valve (Not supplied)
E
Loop (Temporary or Permanent)
A filling point connection on the central heating return pipework must be
provided to facilitate initial filling and pressurising and also any subsequent
water loss replacement/refilling.
The filling method adopted must be in accordance with all relevant water
supply regulations and use approved equipment.
Your attention is drawn to:
for GB: Guidance G24.2 and recommendation R24.2 of the Water Regu
lations Guide.
for IE: the current edition of I.S. 813 Domestic Gas Installations.
A Cold mains in
B Heat return
The sealed primary circuits may be filled or replenished by means of a
temporary connection between the circuit and a supply pipe, provided a
"Listed" double check valve or some other no less effective backflow pre
vention device is permanently connected at the inlet to the circuit and the
temporary connection is removed after use.
When the optional permanent filling link is fitted it is not necessary to re
move any part of it after filling or re-pressurising.
5.6.2 Domestic hot water circuit
A
Boiler
B
Expansion vessel
C
Check valve
D
Pressure reducer
E
Stop tap
F
To hot tap
G
Other tap outlets
All DHW circuits, connections, fittings, etc. should be fully in accordance
with relevant standards and water supply regulations.
Your attention is drawn to:
for GB: Guidance G17 to G24 and recommendation R17 to R24 of the
Water Regulations Guide.
for IE: the current edition of IS 813 Domestic Gas Installations.
Fig.25
"Easy-Fill" permanent filling link
PN-0000633
Fig.26 System filling circuit
PN-0000347
A
B
C
C
D
E
Fig.27 Circuit plan
PN-0000350
A
B
G
C
D
E
F