P17 Pump overrun time in heating mode (01-240 minutes) 03
P18 Burner ignition delay in CH mode (00-10 minutes) - 00=10 seconds 03
P19 Manufacturer information 07
P20 Pump overrun time in DHW mode (seconds) 30
P21
Anti-legionellosis function (°C) 00…54 = Disabled - 55…67 = Enabled
(set the desired temperature value)
00
P22 Manufacturer information 00
P23 Maximum DHW setpoint temperature (ACS) 60
P24 Manufacturer information 35
P25 No water safety device 02
P26..P31 Manufacturer information --
P32..P41 Diagnostics (See SERVICE Instructions) --
P67
Open Therm (OT) settings (See SERVICE Instructions
)
00 = Plug & Play
00
14.1 ADJUSTING MAXIMUM HEATING POWER
The maximum heating power of the boiler can be reduced to suit the requirements of the heating system it serves. A table showing
parameter P13 values according to the desired maximum power model is shown below for each single boiler
To access and edit parameter P13 values, proceed as described in the PARAMETER SETTINGS section.
Boiler model - PARAMETER P13 (%) / Heating output (kW)
kW 1.24 20 - 24 28
3,5 0 0
4 2 2 0
5 7 7 4
6 12 12 8
7 17 17 13
8 22 22 17
9 27 27 21
10 32 32 25
12 41 41 33
14 51 51 42
16 61 61 50
18 71 71 58
20 80 80 67
22 90 75
24 100 86