– 31 –
3. Verify draft inducer pressure switch (Fig. 22)
operation.
A. Set oven control to call for heat and make
sure convection fan is running.
B. Once ame is established, disconnect tubing
from draft inducer pressure switch. Burner
ame should go out.
C. Reconnect tubing. Burner should establish
a ame. If not, contact your local Baxter
authorized service oce.
Verify Operation of Steam
1. Check steam system for proper operation.
A. Turn the water supply on.
B. Turn oven on and set to normal bake
temperature.
C. Allow oven to preheat for 30 minutes.
D. Set control to call for steam.
E. Observe operation. If steam is not observed, contact your local Baxter authorized service oce.
After completion of the owner PM procedure, you will need to contact a qualied servicer for any
needed repairs.
Keep a copy of the Owner Preventive Maintenance Checklist for your records.
Fig. 22