ENUSER’S MANUAL RTI
47
NOT WEIGHED PRODUCTS WITH A MOVING PRICE
Having no weight situated on the platter, choose the PLU, pressing directly on the wished key
~ Use the balance as
usually, introducing the price, pressing the key and introducing the amount of items via the numerical keyboard, the press the
key again to accumulate.
22.2.2 INDIRECT PLU
Follow, depending on the operation, the procedure described. But to select the PLU the user must press the key , introduce
the number of PLU via the numerical keyboard and continue with the previous procedure.
OTHER OPERATIONS
23. MANUAL OPENING OF THE ELECTRIC CHARGE DRAWER
If the charge drawer is unblocked with the key, the user can open it by pressing for 3 seconds the key
.
24. SAVE FUNCTION ( FOR HEAVY ITEMS)
This function allows to keep the last price used charged for the following operations.
• Press the key
, on the display appears the message
Save.
• Introduce the price or choose PLU and use the device in the usual way.
• To change the fixed value, press the key
and then select the new amount/PLU.
• To disable the function, press the key
again.
25. DATE AND HOUR
When the user is in the normal mode of weighing, he must press the key for 3 seconds. Then highlight with the numerical key-
board the date , following the format dd/MM/YY, press the key to validate and indicate with the numerical keyboard in HHMMSS
format. Press the key to validate. If the user wants to exit from this procedure, he must press the key twice. The balance is
going to return to a mode of normal weighing.
26. BACKLIGHTING
Backlighting can function in 3 different modes: always activated (ON), disabled (OFF) or in automatic mode (AUTO) which switches on
the backlighting when the user is using the balance.
To change this characteristic:
1. Keep the key pressed and then remove the pressure when the screen changes (3 seconds).
2. Press the key to choose On, Off or Auto.
Press the key to save all the parameters.