§ 4-4 SYSTEM INITILAIZE
STEP 1: Power OFF, slide rear SET 1 ON.
STEP 2: Screen shows CAL, Press TARE key until show init
STEP 3: Press MODE key, screen will show NO,
STEP 4:Press + key to show YES, Press MODE key to confirm END .
STEP 5: Finish initialize, Slide SET and back to normal mode.
§ 4-5 Accumulation
4-5-1 Display Accumulation
In MODE 2 Status ,
Press TARE keythe screen will show its total count.
Press TARE again, the screen will show Accumulation.
Press ZERO key more than 2 seconds will escape.
4-5-2 Clear Accumulation
Press TARE key more than 2 seconds will show CLR A.C.
Press MODE key to clear count and accumulation.
Press ZERO key more than 2 seconds will Escape.
CHAPTER 5 SET POINTS
§ 5-1 SET POINTS
5-1-1 Change Set point code and Set point values
Press ZERO key to show Final. Press Mode key to show 000.000 , Use +/ -/ < key to set Final
Values. Press Mode key to confirm the Final Value.
Press Mode key to show SP1, Press Mode key to show 000.000 , Use +/-/ < key to set Sep
point 1 values. Press Mode key to confirm the SP1 value.
Press Mode key to show SP2, Press Mode key to show 000.000 , Use +/-/ < key to set Sep
point 2 values. Press Mode key to confirm the SP2 value.
Press Mode key to show FREE, Press Mode key to show 000.000 , Use +/-/ < key to set Free
fall values. Press Mode key to confirm the Free fall value.
Press Mode key to show Hi, Press Mode key to show 000.000 , Use +/-/ < key to set Hi limit
values. Press Mode key to confirm the Hi value.
Press Mode key to show Lo, Press Mode key to show 000.000 , Use +/-/ < key to set Lo limit
values. Press Mode key to confirm the Lo value.
Press ZERO key more than 2 Seconds to leave.