Technical data
Type
Control unit dimensions (W x H x D): approx. 200 x 400 x 155 mm incl. mounting brackets
approx. 200 x 400 x 184 mm incl. mounting brackets and main switch
Assembly Vertical
Supply voltage via L1, L2, L3, N, PE: 400 V 3~N PE ±10%, 50...60 Hz
Power consumption of the control unit: max. 30W when fitted to full capacity
Power output T1 / N (230 V): corresponds to supply voltage, fused with 6.3A fuse
Power output 24 VDC (±10% at rated voltage 230 V) max. 500 mA
Inputs (FE 1 – FE 8): typ. 24 VDC / <10mA +/- 20%
All inputs must be connected potential-free:
min. signal duration for input control commands: > 100 ms
Safety chain / EMERGENCY STOP It is imperative that all inputs are connected potential-free
Contact load rating: 200mA / 30VDC
Safety inputs SE1 and SE2 For electric safety edges with 8.2 kΩ / 1.2 kΩ terminating resistance and for dynamic
optical systems 5.1 kOhm slack rope switch/wicket door switch
Secure functions
(EN ISO 13849-1:2008)
Safety edge:SE1, SE2 Category 2 / PL d
Optoelectronic safety edge
OSE: FE1
Category 2 / PL d
Light barrier with testing Category 2 / PL d
Emergency Stop Category 2 / PL d
Path limitation Category 2 / PL c
Membrane keypad Category 2 / PL d
Safety radio receiver Category 2 / PL d
Relays Rel1 and Rel2 For inductive switching loads, suitable interference suppression measures should be
put in place
Change-over contact potential-free
3A / 250VAC; 3A / 30VDC
Relay Rel3 Potential-free normally open contact
0.5 A/24 VDC
Output power (motor) Relay: P
max
: 2.0kVA
Contactor: P
max
: 4.5kVA
Temperature range Operation: -10...+40°C
Storage: -20...+70°C
Humidity Up to 95%, non-condensing
Vibration Low-vibration installation, e.g., on a brick wall
Degree of protection IP54 (optional: 65)
Weight Approx. 3.5 kg
Attention
Contacts used once for power switching cannot switch any further small currents.